Full list of Specifications in order (test code sheet number and type of test)
- 1111.1 Closure
- 1111.2 Closure
- 1111.3 Closure - Opening and reseating pressure test
- 1111.4 Closure - Temperature Conditions *1
- 1111.5 Leaktightness test
- 1111.6 Closure at set outlet pressure
- 1111.7 Closure - Diverter
- 1111.8 Closure under high downstream pressure
- 1111.9 Pressure tightness under a low reverse pressure differential
- 1111.10 Pressure tightness under a high reverse pressure
- 1111.11 Closure under low downstream pressure
- 1111.12 Closure - diverter
- 1111.13 Check valve closing pressure (downstream checkvalve only)
- 1111.14 Leak tightness of the downstream checkvalve. High pressure
- 1111.15 Leak tightness of the upstream checkvalve at low pressure
- 1111.16 Relief valve operation
- 1111.17 Pressure fluctuation
- 1111.18 Leak tightness of the downstream check valve. High pressure
- 1111.19 Closing pressure of the downstream check valve
- 1111.20 Pressure tightness under a low reverse pressure differential
- 1111.21 Leak tightness test
- 1111.22 Leak tightness test
- 1111.23 Tightness test – high pressure
- 1112.1 Porosity
- 1112.2 Porosity
- 1112.3 Body strength
- 1112.4 Porosity
- 1112.5 Porosity
- 1112.6 Porosity
- 1112.7 Porosity
- 1112.8 Porosity
- 1112.9 Body strength
- 1112.11 Porosity
- 1112.12 Porosity
- 1112.14 Porosity
- 1112.15 Body strength
- 1112.17 Body strength
- 1113.1 Joint effectiveness
- 1113.2 Joint effectiveness
- 1113.5 Joint effectiveness
- 1211.1 Endurance
- 1211.2 Endurance
- 1211.3 Endurance
- 1211.4 Endurance
- 1211.5 Endurance test
- 1211.6 Endurance
- 1211.7 Endurance
- 1211.8 Endurance test
- 1211.12 Endurance
- 1211.14 Endurance
- 1211.15 Flushing device physical endurance and leakage
- 1211.16 Endurance
- 1211.17 Performance test of air bubble unvented hot water storage systems
- 1211.18 Endurance
- 1211.19 Endurance - reliability characteristics
- 1211.20 Endurance test
- 1211.21 Endurance - remote/non-touch method of actuating the water supply
- 1211.22 Endurance - hot test
- 1211.23 Endurance test
- 1211.24 Durability test
- 1211.25 Endurance test
- 1211.26 Endurance test
- 1212.1 Accelerated ageing
- 1212.3 Accelerated ageing
- 1212.4 Accelerated ageing
- 1212.5 Accelerated ageing
- 1212.6 Accelerated ageing *2 & *3
- 1212.7 Accelerated ageing
- 1212.10 Accelerated ageing
- 1311.1 Deflection
- 1311.2 Deflection
- 1311.3 Deflection prevention (inspection only)
- 1311.4 Deflection
- 1311.5 Deflection
- 1312.1 Deformation
- 1312.2 Deformation
- 1312.3 Bending strength
- 1312.5 Deformation (Boss distortion)
- 1312.6 Deformation
- 1312.7 Impact
- 1312.8 Deformation
- 1312.9 Deformation
- 1312.10 Impact
- 1312.11 Bending strength
- 1312.12 Bending strength
- 1312.13 Bending strength
- 1312.14 Bending strength
- 1312.15 Bending strength
- 1312.16 Bending strength
- 1312.17 Bending strength
- 1313.1 Impact
- 1313.2 Impact
- 1313.4 Verification of valve not jamming
- 1313.7 High velocity test
- 1314.1 Tension - (Resistance to pull-out of assembled joints - single pull)
- 1314.4 Tension - cold embrittlement
- 1314.5 Compression - front thrust test
- 1314.7 Tension - (Resistance to pull-out of assembled joints - single pull)
- 1314.8 Tension - (Resistance to pull-out of assembled joints - multiple pull)
- 1314.9 Tension - (Resistance to pull-out of assembled joints – single pull)
- 1314.10 Tension - (Resistance to pull-out of assembled joints - single pull)
- 1314.11 Tension - (Resistance to pull-out of assembled joints - single pull)
- 1314.12 Tension - (Resistance to pull-out of assembled joints - single pull)
- 1314.13 Tension - (Resistance to pull-out of assembled joints - single pull)
- 1314.14 Tension - (Resistance to pull-out of assembled joints - single pull)
- 1314.15 Tension - (Resistance to pull-out of assembled joints - single pull)
- 1315.1 Torque - operating mechanism
- 1315.2 Torque - Connection and Disconnection
- 1315.4 Torque - backnuts
- 1315.6 Torque - backnuts
- 1321.1 For deleterious films in copper tube
- 1411.1 Dezincification resistance
- 1411.2 Corrosion protection
- 1411.3 Flushing device: chemical endurance
- 1412.1 Corrosion protection
- 1430.1 Temperature rise in integral cold water cistern
- 1511.1 Opening and closing of the relief valve
- 1511.2 Flush Rate
- 1511.4 Flow rate
- 1511.5 Flow rate
- 1511.6 Flow rate / splashing
- 1512.1 Consumption
- 1512.2 Consumption
- 1512.3 Consumption
- 1512.5 Consumption
- 1512.8 Consumption
- 1512.9 Consumption (regeneration wastewater volume)
- 1512.10 Paper discharge for reduced flush volume
- 1512.11 Solids discharge and after flush volume for maximum flush
- 1512.12 Wash of bowl
- 1611.1 Prevention of contamination - primary to secondary circuits
- 1611.2 Prevention of waste from frost damage
- 1611.3 Prevention of waste and contamination - materials and construction
- 1611.4 Accessibility for cleaning
- 1611.5 Means for connection and disconnection
- 1611.6 Provision for backflow prevention
- 1611.8 Visual inspection - seal to be readily renewable
- 1611.9 Visual inspection - fixing of washer plate
- 1611.10 Visual inspection - means of operation
- 1611.11 Visual inspection - means of renewing seat and washer, or seal and washer, if so required
- 1611.14 Visual inspection - manually operated easing gear
- 1611.15 Visual inspection, method of operation of dual flush cisterns
- 1611.16 Liquid contaminant, dye retention
- 1612.1 Water tightness of siphonic apparatus
- 1711.2 Operating efficiency
- 2111.1 Effect upon water quality *4
- 2111.2 Effect upon water quality
- 2111.3 Effect upon water quality
- 2114.2 Opacity
- 2211.1 Contamination Test
- 2211.2 Contamination - vacuum when submerged
- 2211.3 Contamination - mixing of primary and secondary
- 2211.4 Contamination - mixing of primary and secondary circuits
- 2211.5 Contamination - mixing of primary and secondary circuits
- 2211.11 Vacuum test tightness of the upstream check valve
- 2212.1 Contamination - vacuum test under fault conditions
- 2212.3 Vacuum / Dimensional
- 2212.4 Contamination - antisiphonage test
- 2212.6 Vacuum test *5
- 2212.8 Contamination - vacuum test, including under fault conditions
- 2212.9 Vacuum test
- 2212.10 Dimensional - Air gap to drain
- 2212.11 Vacuum test tightness of the upstream check valve
- 2212.12 Vacuum test - totally failed condition
- 2212.13 Vacuum test without moving element
- 2212.14 Vacuum test
- 2212.15 Vacuum test
- 2212.16 Vacuum test
- 2212.17 Vacuum
- 2212.18 Vacuum test
- 2212.19 Opening pressure
- 2212.20 Backflow prevention. Regulator’s specification for WC suites
- 2213.1 Dimensional
- 2213.3 Contamination - dimension of air vent - gas/water air space
- 2213.4 Contamination - air gap dimension
- 2213.5 Visual Inspection - compatibility of cartridge and housing dimensions, sealing etc
- 2213.7 Visual inspection
- 2213.8 Pressure difference between the upstream and the intermediate zone
- 2213.10 Visual inspection - check valve operation
- 2213.11 Visual inspection - check valve operation
- 2213.12 Dimensional
- 2213.13 Pressure differential at valve closure
- 2213.14 Dimensional
- 2213.15 Dimensional
- 2213.16 Dimensional
- 2213.17 Dimensional
- 2213.18 Dimensional
- 2213.19 Dimensional
- 3212.1 WC flush volume and water seal depth
- 3212.2 Volume of discharge
- 5011.1 Measurement of linear dimensions
- 5011.3 Measurement of dimension
- 5011.5 Measurement of dimension
- 5011.6 Water Seal depth
- 5011.7 Warning pipe and overflow provision
- 5021.2 Measurement of dimension - area
- 5021.3 Measurement of dimension
- 5031.1 Dimension - capacity
- 5031.2 Dimension - capacity
- 5031.3 Dimension - lifting effort
- 6001.1 Marking for identification *6 & *7